advia 2120 hematology analyzer manual

File Name:advia 2120 hematology analyzer manual.pdf
Size:1884 KB
Type:PDF, ePub, eBook, fb2, mobi, txt, doc, rtf, djvu
Category:Book
Uploaded4 May 2019, 23:56 PM
InterfaceEnglish
Rating4.6/5 from 758 votes
StatusAVAILABLE
Last checked9 Minutes ago!

advia 2120 hematology analyzer manual

This is how Siemens delivers Practical Automation to your hematology lab. The ADVIA 2120i System delivers the gold-standard in testing methodology for optimum results while offering the simplicity and flexibility you need for easy integration into your lab. ADVIA technology utilizes peroxidase staining—the gold-standard in differential testing. This primary methodology of the ADVIA Hematology Systems also provides a secondary total white cell count that acts as an internal QC check to monitor sample integrity. With integrated and automated solutions from Siemens, you can scale from stand-alone instrumentation to complete automation as your productivity needs change. Would you like to provide detailed feedback. Sign in Forgot Password. My Bench Close Sign In Not A Member. Sign Up Join MedWrench OK name type Receive Summary Emails. The ADVIA 2120 and ADVIA 2120i Hematology Systems are fully automated analyzers that perform Complete Blood Counts with Differential, Reticulocyte analysis and Two-dimensional Platelet analysis using a combination of Laser Light Scatter and cytochemical staining, providing higher confidence and better efficiency. CSF analysis reduces manual operator intervention and improves turn around time. In addition, Flexible sampling modes and onboard reagents allow you to maximize your precious resources: blood, operator safety, workspace, and storage areas. Has the analyzer been approved for this. Is it truly better than the human eye in reporting.Two dimensional optical platelets analyze both extra-cellular and intracellular properties, ensuring that large platelets are included in your counts, and known interferences are not. This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details. All Rights Reserved. And by having access to our ebooks online or by storing it on your computer, you have convenient answers with Advia 2120 User Manual.

To get started finding Advia 2120 User Manual, you are right to find our website which has a comprehensive collection of manuals listed. Our library is the biggest of these that have literally hundreds of thousands of different products represented. I get my most wanted eBook Many thanks If there is a survey it only takes 5 minutes, try any survey which works for you. In the latter case, pleaseLimit of detection (LoD) and quantitation (LoQ), repeatability, and inaccuracy were assessed. RESULTS:Good agreement between the automated methods with dedicated software and the manual method for %PMN and %MN was obtained for leukocyte differentiation in ascitic and pleural fluids, while correlation with the manual method for PD fluid was poor, both with and without the dedicated software. CONCLUSIONS:We demonstrated that the automated differentiation of leukocytes with dedicated software on the ADVIA2120 analyzer for body fluids is a good alternative to the microscopic reference method for peritoneal and pleural specimens, but not for PD fluids. This may be because the snippet appears in a figure legend, contains special characters or spans different sections of the article. Limit of detection (LoD) and quantitation (LoQ), repeatability, and inaccuracy were assessed. Results Good agreement between the automated methods with dedicated software and the manual method for % PMN and % MN was obtained for leukocyte differentiation in ascitic and pleural fluids, while correlation with the manual method for PD fluid was poor, both with and without the dedicated software. Conclusions We demonstrated that the automated differentiation of leukocytes with dedicated software on the ADVIA 2120 analyzer for body fluids is a good alternative to the microscopic reference method for peritoneal and pleural specimens, but not for PD fluids.

Keywords: automated hematology analyzer, biological liquid application ADVIA 2120 software, body fluids, differentiation of leukocytes, microscopic method 1.?INTRODUCTION Leukocyte count and differentiation in body fluids offer important information for the diagnosis and treatment of various medical conditions. Consequently, over the last years, conventional blood cell counters and automated urine analyzers have been evaluated for the quantification of cells in body fluids. 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21 It is not easy to obtain a good result with automated methods for leukocyte differentiation on body fluid samples: interference from mesothelial cells, macrophages, lymphoma cells, and metastasis may lead to incorrect results. Each chamber contains a grid with 10 squares. MN cells consisted of lymphocytes, monocytes, macrophages, and mesothelial cells, while PMN cells were comprised of neutrophils, eosinophils, basophils, and mast cells. 26. Samples analyzed without the dedicated software were processed with the default run screen for blood samples. All measurements on ADVIA2120 were performed according to the manufacturer’s specifications. 27 We analyzed 87 samples as body fluid samples, with dedicated software (39 ascitic, 32 pleural, and 16 PD fluid), and 106 fluids as blood samples, without dedicated software (49 ascitic, 16 pleural fluids, 41 PD fluid samples). We carried out the company’s rinse cycle between each of the analyzed body fluids to minimize carryover from previous analyses. We considered only fluids with TNC higher than the calculated LoD.As for the other types of fluids, only samples with elements above the calculated LoD were considered. For this reason, numerous automated analyzers developed a way for studying body fluids. The ADVIA2120 analyzer has a dedicated body fluid mode that provides a leukocytes differential count consisting of PMN and MN cell absolute counts and percentages.

To our knowledge, this is the first study about leukocyte differentiation using ADVIA2120 dedicated software in ascitic, pleural, and PD fluid. With an automated method, we evaluated 106 samples as blood samples. The body fluid dedicated software was installed at a later time, and with it, the following 87 specimens were analyzed. We observed good performance for TNC, WBC counts, and %MN for repeatability of automated methods, and a narrower CV range for %PMN was obtained with the dedicated software. Leukocytes’ CV obtained with the manual method was higher than with automated methods, based on the high imprecision of the manual procedure. We obtained good LoD results for automated methods, comparable to the declared manufacturer low limit of linearity. For WBC count, we observed a wider inaccuracy than for TNC count. Furthermore, there was good proportionality between the results of pleural fluids for leukocyte differentiation obtained with automated and manual methods, but as for peritoneal fluids, there was a small but constant overestimation for %PMN. We know that mesothelial cells usually cause automated flags, and this is more frequent in pleural fluids. Pleural fluids’ results analyzed without dedicated software did not have a good agreement with the manual method’s results. We consider that the constant overestimations by software of ADVIA2120 for %PMN for peritoneal and pleural fluids are not clinically relevant (even if values of %MN are bigger than %PMN, we know that the results of %PMN are clinically more important); we noticed that bigger differences for each paired count were in the lowest absolute count of leukocytes (data not shown). For %PMN and %MN of dialytic fluids, we did not observe a significant agreement between the two automated methods and the manual method. It is possible that these kinds of body fluids are more enriched of these factors.

This is plausible because peritoneal dialysis fluid is a physiologic synthetic liquid introduced into the peritoneal cavity for normalizing fluid, electrolytes, and solute balance in the body using the principles of ultrafiltration and diffusion, and what we analyze is the lavage fluid that is removed from the cavity. Aulesa et al. in 2003 and Froom et al.We observed narrower CV ranges for WBC and TNC counts in ADVIA2120 with respect to ADVIA120. CV for %MN were better for ADVIA2120 with and without dedicated software, while CV for %PMN was not improved. We observed that inaccuracy for ADVIA2120 was better than ADVIA120 for leukocytes, but not for %PMN and %MN, and this is not surprising inasmuch as this manuscript highlighted misclassification in PMN and MN counts in some kinds of body fluids, in particular, dialysis fluids. Froom et al. obtained good agreement for neutrophil differential counts for ascitic fluids, even if they analyzed only 5 samples. A limit of our study is the small number of cases for some types of fluids analyzed; we are also aware that dedicated quality control material is unavailable for body fluids. We observed that the most significantly different %PMN and %MN cells between manual and automated methods were due to the presence of mesothelial cells, lymphoma cells, or rarely nonhematopoietic malignant cells (data not shown). It was crucial to evaluate these samples by microscope. Moreover, abnormal test results or plots were verified with microscopic revision. In conclusion, we demonstrate that the body fluid dedicated software of the ADVIA2120 shows a good agreement for leukocyte differentiation for ascitic and pleural fluids compared to the manual method (“gold standard”), but not for dialysis fluids. Furthermore, automated methods eliminate the wide interobserver variability seen in manual microscopy, it reduces the number of samples submitted for microscopy and is available 24 hours a day.

Supporting information Click here for additional data file. (85K, doc) Click here for additional data file. (133K, doc) Notes The management of ascites in cirrhosis: report on the consensus conference of the International Ascites Club. Kjeldsberg CL, Knight JA. 1986. Xu R, Chen Y, Luo S, et al. Manoni F, Tinello A, Fornasiero L, et al. Riedl JA, Dinkelaar RB, van Gelder W. Automated morphological analysis of cells in body fluids by the digital microscopy system DM96. Bourner G, De La Salle B, George T, et al. ICSH guidelines for the verification and performance of automated cell counters for body fluids. Aulesa C, Mainar I, Prieto M, Cobos N, Galimany R. Use of the Advia120 hematology analyzer in the differential cytologic analysis of biological fluids (cerebrospinal, peritoneal, pleural, pericardial, synovial, and others. De Smet D, Van Moer G, Martens GA, et al. Lippi G, Cattabiani C, Benegiamo A, et al. Evaluation of white blood cell count in peritoneal fluid with five different hemocytometers.Buoro S, Gustinetti R, Dominoni P, et al. Danise P, Maconi M, Rovetti A, et al. Cell counting of body fluids: comparison between three automated haematology analysers and the manual microscope method. Harris N, Kunicka J, Kratz A. The ADVIA 2120 hematology system: flow cytometry based analysis of blood and body fluids in the routine hematology laboratory. Gunetti M, Castiglia S, Rustichelli D, et al. Validation of analytical methods in GMP: the disposable Fast Read 102W device, an alternative practical approach for cell counting. McEnroe RJ, Durham AP, Goldford MD, et al. Clinical and Laboratory Standards Institute. Evaluation of Precision of Quantitative Measurement Procedures; Approved Guideline—Third Edition. Koepke JA, Van Assendelft OW, Brindza LJ, et al. Reference Leukocyte (WBC) Differential Count (Proportional) and Evaluation of Instrumental Methods; Approved Standard—Second Edition. Szamosi DI, Bautista JM, Cornbleet J, et al.

Body Fluid Analysis for Cellular Composition; Approved Guideline. Siemens. Froom P, Diab A, Barak M. Automated Evaluation of Synovial and Ascitic Fluids With the Advia 2120 Hematology Analyzer.How are we doing. Europe PMC is part of the ELIXIR infrastructureEurope PMC is a service of theIt includes content provided to the. To browse Academia.edu and the wider internet faster and more securely, please take a few seconds to upgrade your browser. You can download the paper by clicking the button above. Related Papers Atlas of Comparative Diagnostic and Experimental Hematology By Mohammad Rifky Evaluation of the ADVIA 120 for analysis of canine cerebrospinal fluid By Ronaldo Costa CD3200 By Mon Mon Blood Cells - A Practical Guide By Nourhan Mohammed Erythroblasts count by ADVIA 2120i in patients with thalassemia and sickle cell disease and in newborns By Sabrina Buoro READ PAPER Download pdf. In our area, service response was 1-2 days. Very good differentiation, reproducibility and precision. It is very good and produces accurate result for all parameters and morphology. Csf total count is also available. This machine is used for research and leukaemia patents. One parameter LUC (Large unstained cells) makes the manual differential stain and sees all abnormal cells. However the Advia 2120 does require lots of maintenance. More time consuming for micro volumes. Large amount of sample parameter data provided for each sample and from such small volumes. Requires specialist operation to get the most from the instrument. Currently work with this analyzer as well as Sysmex XT1000. Advia is pale in comparison. Continuously down, continuously cleaning, poor differential analysis. Too much downtime for an instrument in 2013. Our automatic slide maker originally would jam and break slides, however with the help of service it started to work very well.

Peroxidase stain is the gold standard for WBC differentials, and therefore, provides better agreement with your technologists’ manual results- no doubts, higher confidence, better efficiency with the Siemens Advia 2120. Advia 2120 5-Star rating. The ADVIA 2120 - A real crowd pleaser. Flexible sampling modes of the Siemens Advia 2120 and onboard reagents allow you to maximize some of your precious resources: blood, operator safety, workspace, and storage areas. The Siemens Advia 2120 Exceeds your expectations. CSF Assay: Automated WBC, RBC, differential, PMN and MN results in less than 1 minute from aspiration. Customized Options with the ADVIA 2120 to Manage Your Workload - ADVIA 2120 Multispecies Software from Siemens The Advia 2120 supports 21 Species and Strains Up to 30 additional user-defined species Top-List Clinical Products Most Reviewed by You 14 Apr 2016 Editorial Article Siemens Healthcare Diagnostics: Advances in Hematology, Hemostasis, and Drug Testing Introduced at AACC 2015 19 Oct 2015 Product News Siemens Reveals New Clinical and Workflow IVD Solutions at AACC 2015 29 Jul 2015 Top-List Most Reviewed Products in the Clinical Directory 23 Jun 2015 Industry News New Novation Agreements Awarded to Siemens for Central Laboratory Solutions 08 May 2012 Easy It’s quick and simple to do Fast Your inquiry will be delivered straight to the manufacturer Free You’re under no obligation Secure We only pass your details on to trusted suppliers at your request Save time Submit your details once and make multiple inquiries. If you continue browsing the site, you agree to the use of cookies on this website. See our User Agreement and Privacy Policy.If you continue browsing the site, you agree to the use of cookies on this website. See our Privacy Policy and User Agreement for details.If you wish to opt out, please close your SlideShare account. Learn more. You can change your ad preferences anytime. Why not share!

I would not have had the confidence to bid without your help. I will buy my next car at auction too. ??? Here's the link to the FREE report ??? The analyzer uses whole blood sample to provideCBC ResultsPlatelet ResultsCSF Assay Results (Optional)Granulocytes, Myeloperoxidase Deficiency. RBC and PLTClumps, Large PlateletsManual Closed Tube 175 ?L. Manual Open Tube 175 ?LDatabase 10,000-patient storage capacityWorkstation SpecificationsA- The analyzer contains all the electronic, pneumatic,Wash solution except Sheath RINSE. The waste system is a sub component of analyzer.The auto sampler is a rack-style sampler with aPressing the push toReaction Chambers are:The rear disk is stationary. The front disc rotates to shear orThe use of a sheath streamThis optical assembly is shared byThe use of a sheath stream inThe system uses the readings to deriveAfter On is pressed,To exit, press Standby.This container can be a stand-aloneWhen the fluidThe analyzer will not aspirate any moreThe sheath fluid surrounds the dilutedHaematology Controls (Low, Normal and High) thatAllow to reach the controls room temperature beforeTime 6.5 min. Analyser mode should be ready to run. At utilities menu, select Hydrolytic function. Select system wash, select 1 cycle and press. Start. NOTE: Automatic wash cycle has to be atClean air filter. Clean 50Um plungerReplace 4 drain filterNow customize the name of a clipboard to store your clips. The Siemens Advia 2120 hematology analyzer is routinely available from Block Scientific in refurbished condition. This bench-top analyzer designed for medium- to large-volume laboratories, uses a combination of light scatter, cytochemical staining, and nuclear density on two independent channels to measure the total and differential white cell counts. Operating with a cyanide free method for hemoglobin measurement, the analyzer features a new user interface. The Advia 2120 system can routinely analyze biological fluid samples in addition to blood.

Malaria is a life-threatening mosquito-borne blood disease caused by a Plasmodium parasite. Though eliminated from the United States in the early 1950s, approximately 1,700 cases of malaria are reported every year in the U.S. According to the report from WHO, there were 212 million new cases of malaria worldwide in 2015 (range 148-304 million). Siemens Healthineers hematologist Jan van den Boogaart and his Austrian research colleague Prof. Oliver Hayden (who earlier worked at Siemens Healthineers), has developed the first automated, computer-based blood test for malaria. Combining medicine and information sciences, the test is based on a computer algorithm that detects infections with unprecedented accuracy. The European Patent Office has honored these inventors with the 2017 European Inventor Award. The technology is based on a conventional hematology analyzer, specifically Siemens' Advia 2120 system, a high-throughput system for complete blood count and the differentiation of blood cells. Instead of looking for the presence of malaria pathogens in the blood, they used information technology to detect the disease's damaging effects, as indicated by key blood parameters such as lowered platelet counts. Previous detection methods for malaria include a time-intensive microscopic procedure that requires a technician working roughly an hour in the lab or a dip-and-react test for malaria antigens. Linear discriminant analysis (LDA), a statistical method was used for the new discovery. The scientists ran a statistical analysis of the blood parameters of the malaria samples and non-malaria samples. Widely used in clinics, this automated hematology analyzer can create hemograms with 300 to 500 parameters at the rate of 120 blood samples per hour. With near-100% accuracy, the system identifies malaria in a blood sample even if only low levels of pathogens are present.

The great advantage is the high throughput at lower cost compared to other methods such as microscopic examination.It streamlines workflow by eliminating most manual steps in hematology labs. Standard testing methodology in this system provides optimum results and offers flexibility and simplicity for easy integration in labs for 30 parameters with 5 part differential analysis. Operating with a cyanide free method for hemoglobin measurement, the analyzer features a new user interface. Once the user has seen at least one product this snippet will be visible. Please enable it to take advantage of the complete set of features!Get the latest public health information from CDC. Get the latest research from NIH. Find NCBI SARS-CoV-2 literature, sequence, and clinical content:.In addition, some advanced instruments provide novel parameters, such as the hemoglobin content of reticulocytes or the percentage of hypochromic cells, and are capable of analysis of a variety of body fluids. Bayer recently introduced the ADVIA 2120 system as an automation-ready cell counter for mid- to high-volume testing in the clinical laboratory. This instrument, which builds on the established technology of the ADVIA 120 system, operates with a cyanide-free method for hemoglobin measurement, has a new user interface, and can routinely analyze biological fluid samples in addition to blood. We used 749 samples from 6 worldwide trial sites to evaluate the clinical performance of this new device. Use of the novel cyanide-free method for hemoglobin measurement had no clinically significant impact on hemoglobin results, even in patients with hemoglobinopathies. We concluded that the ADVIA 2120 system has clinically equivalent performance to the ADVIA 120 system.